Deluxe Combustion Efficiency Analyzer with Datalogging and optional Infrared Printer
|
| |
TPI 714 Boiler Flue Gas Combustion Analyzer with NO/NOx
Features
•
Measure Oxygen, Carbon Monoxide, Nitric Oxide, Calculate NOx, CO/CO2 Ratio
• Calculates Boiler Combustion Efficiency
• Store function to save up to 50 readings
• Data Logging with time and date stamp
• Pump driven for fast response
• Built-in differential manometer with 0.001" H2O resolution
• Built-in differential thermometer
• Data Logging with time and date stamp
• Push on fittings for fast and easy use
• Will not shut off if 15ppm CO is present for increased safety
• Large easy to read backlit display
• Optional A740 IR printer available for hard copies of test results |
|
TPI 714 Combustion Analyzers |

|
TPI 714 Prices Start at $1795.00
|
|
|
The TPI 714 combustion analyzer feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time
after initial startup. The 714 analyzers also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on.
Applications
• Tuning of residential and furnaces and domestic boilers
• Ambient and stack testing for Carbon Monoxide
• Carbon Monoxide safety measurements in and around combustion sources
• Measure NO and calculates NOx
• Detecting gas leak in gas lines and around gas fueled appliances
• Dual input differential manometer with 3 selectable units of measure: kPa, mBar, inH20
|
|
Measurement Parameter Specifications
Carbon Monoxide (CO) Measurement Range: 0 to 10,000 ppm
Resolution: 1 ppm
Accuracy: ±5ppm or 5% of reading whichever is greater
Oxygen (02) Measurement Range: 0 to 25%
Resolution: 0.1%
Accuracy: ±0.3% Carbon Dioxide (CO2) Range: 0 to 25%
Resolution: 0.1% Calculated Value
Nitric Oxide Measurement Range: 0 to 5,000ppm
Resolution: 1ppm
Accuracy: <100ppm: ±5ppm <1000ppm ±5% >1000ppm: ±10ppm
NOX Measurement Range: 0 to 5,250
Resolution: 1ppm
Calculated Value
Temperature Measurement Range: -40 to 1472°F (-40 to 800°C)
Resolution: 1°F or °C
Accuracy: (K-type) ±0.3%, ±2°F or ±1°C
Draft/Pressure Measurement Selectable Ranges mBar, kPa, and inH2O Ranges: -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20
Resolution: 0.01mBar
Accuracy: ±0/5% fsd
Gross/Net Efficiency Range: 0 to 100%
Resolution: 0.1%
Calculated Value
CO/CO2 Ratio Range: 0 to 0.999
Resolution: 0.001
Calculated Value
Instrument Specifications
Operating Temperature: 14°F to 122°F (-10°C to 50°C)
Charger Input Voltage: 110V to 230V (50/60Hz)
Selectable Fuels: Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Display Type: Backlit 3 line LCD
Data Storage: 10 Locations
Data Logging: Yes (5 pages)
Print Capability: Yes, via optional IR printer (A740)
PC Communication: Yes via optional IR adapter (A767)
Date & Time Function: 24 Hour Real Time Clock
Dimensions: 200mm x 90mm x 60mm
Weight: 500g
Conformity: BS7927 (and the draft BS7967)
|
|
|
Gas Measurement Parameters
|
Gases
|
Range
|
Resolution
|
Accuracy
|
|
Oxygen
|
0 to 25%
|
0.1%
|
±
0.3%
|
|
Carbon Monoxide
|
0 to 10,000 ppm
|
1 ppm
|
±
5 ppm or 5%
|
|
Nitric Oxide
|
0 to 5000 ppm
|
0.1%
|
±
5 ppm or 5%
|
|
Carbon Dioxide
|
0 to 25%
|
0.1%
|
Calculated
|
|
NOx
|
0 to 5250 ppm
|
1 ppm
|
Calculated
|
|
CO/CO2 Ratio
|
0 to 0.999
|
0.001
|
Calculated
|
|
Combustion Eff.
|
0 to 100%
|
0.1%
|
Calculated
|
|
|
|
|
|
TPI 714 meter, Rubber Boot, Soft Carrying Case, Flue Sampling Probe, In-Line Filter installed on Flue probe, Spare In-Line Filter (one included), Temperature Probe, Battery
Charger, Mini Pump Protection Filter Assembly and spare filters, Exhaust Spigot (removable), Pressure Tubing, Static Pressure Tips, Barbed to 1/8” NPT fittings (2 each), Gas
Valve Adapter, Adapter Tubing, Instruction Manual.
Click Here To Order:
TPI714A740 Combustion Flue Gas Analyzer for Boiler Maintenance with
IR Printer. Price start at $1945.00.
Includes
TPI 714 meter, A740 Infrared Printer, Rubber Boot, Soft Carrying Case, Flue Sampling Probe, In-Line Filter installed on Flue probe, Spare In-Line Filter (one included),
Temperature Probe, Battery Charger, Mini Pump Protection Filter Assembly and spare filters, Exhaust Spigot (removable), Pressure Tubing, Static Pressure Tips, Barbed to
1/8” NPT fittings (2 each), Gas Valve Adapter, Adapter Tubing, Instruction Manual.
|
|
| |
|
Multifunction Temperature and Process Calibrators,
Thermocouple and mA Calibrators,
Thermocouple and RTD Dry Block Calibrators,
Portable Infrared Thermometers,
Fixed Mounted Industrial Infrared Thermometers,
Thermocouple and RTD 2-wire Head Mounted Transmitters, DIN Rail Mounted Thermocouple and RTD Transmitters,
Temperature and Process Panel Meters, Temperature & Humidity Transmitters, Hand Held Digital Thermocouple Thermometers,
MIST Microprocessor Based Integral Transmitter RTD Temperature
Sensors,
Industrial Test tools and Multimeters, Indoor Air
Quality (IAQ) and Test Meters,
Hand Held Humidity and Air Flow Meters,
Industrial Portable
Refrigerant and Gas Leak Detection Meters,
Pressure Measurement and Calibration Instruments,
Boiler Flue Gas
Combustion Emission Analyzers,
Solar Radiation Meter
Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers
* NY * 10710 Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email: